For stair & steelwork fabricators

From a Height and a Width to a Full Stair Drawing

Give the height to climb, the width and the steel. Metal Draw AI works out the risers, places the landing, and draws the plan, both elevations, the stringer detail and the cut list, ready to quote.

Draw a Stair

Free: up to 20 drawings a month, no credit card.

No CAD experience needed. Check every dimension, connection and code requirement before fabrication.

What you type

Steel stair, total rise 3000, 1000 wide, UPN 180 stringers, checker plate treads with a 280 going, landing at 1500 turning right.

Shop drawing of an L-shaped steel stair climbing 3000 mm: plan with a quarter landing turning right, both side elevations at 30.8°, UPN 180 stringer detail and cut list

30 seconds: from request to drawing and cut list

How a stair job usually goes

  1. Measure the height and the space
  2. Work out risers and going
  3. Draw the stringers and cut angles
  4. Write the cut list
  5. The customer wants it wider
  6. Start again
  • The riser count, the going and the landing height all have to agree, and the landing has to fall exactly on a step.
  • Stringer lengths and cut angles take careful geometry, and a mistake costs steel.
  • One change, wider or turning the other way, ripples through the whole drawing.
  • The drafting time eats into the margin before the quote is even sent.

How it works

  1. 01

    Describe the stair

    The height to climb, the width, the stringer section, the treads and where the landing turns.

  2. 02

    It works out the stair

    Riser count and height, going, pitch, the landing on a riser line, and the comfort rule checked.

  3. 03

    Change it in plain English

    "Make it 1200 wide", "turn left at the landing", "grating treads". The stair is recomputed.

  4. 04

    Check and export

    Review the plan, elevations and cut list, then download them or send your customer a link.

One L-shaped stair, from a sentence to a cut list

The drawings below are the app's own output for this request: the stair is computed from your numbers, not sketched.

1. The request

Steel stair, total rise 3000, 1000 wide, UPN 180 stringers, checker plate treads with a 280 going, landing at 1500 turning right.

The first drawing is at the top of this page: the plan, both side elevations, the stringer detail with its cut angles, and a cut list. It chose 18 risers of 166.7 mm so the landing sits exactly on a step, a 30.8° pitch, and says so.
2. The customer changes the layout

Make it 1200 wide and turn left at the landing.

Updated shop drawing of the steel stair at 1200 mm wide, with the landing turning left
3. The updated drawing: The treads, the landing and its cross members follow the new width, the quarter landing grows to 1340 × 1340, and the second flight now leaves to the left. The stringers stay as they were.

4. The cut list, ready for quoting

  • A — stringer A
    Qty
    4
    Section × size
    UPN 180 × 2764.8
    Process
    Saw cut to the stringer detail
  • B — tread
    Qty
    16
    Section × size
    checker plate 5 × 1200 × 280
    Process
    Cut and bend nosing
  • C — landing side
    Qty
    2
    Section × size
    UPN 180 × 1340
    Process
    Saw cut square
  • D — landing cross member
    Qty
    2
    Section × size
    UPN 180 × 1200
    Process
    Saw cut square
  • E — landing deck
    Qty
    1
    Section × size
    checker plate 5 × 1200 × 1340
    Process
    Cut

5. Export and share

Download the drawing as SVG or PNG and the cut list as CSV, or send your customer a share link. Pro adds PDF for printing and DXF for CNC cutting.

What it changes on a stair job

  • Quote stair jobs sooner.
  • Risers, going and pitch worked out for you, with the comfort rule checked.
  • Stringer lengths and cut angles ready for the saw.
  • A plan and elevations for the customer to approve before you cut.
  • Change the width or the turn without redrawing the stair.
  • No full-time drafter needed.

Compared with how it's done today

  • Today
    Riser count worked out by hand
    With Metal Draw AI
    Risers and going computed from the height
  • Today
    Stringer angles drawn and measured
    With Metal Draw AI
    A stringer detail with lengths and cut angles
  • Today
    Every change redrawn
    With Metal Draw AI
    Changes in plain English
  • Today
    The cut list written separately
    With Metal Draw AI
    The cut list comes with the drawing
  • Today
    Waiting for a drafter to be free
    With Metal Draw AI
    A first draft you make yourself

What it draws today

Drawn and computed

  • Straight stairs, one flight
  • Two flights on a landing, in line or turning 90° (L-shaped)
  • UPN channel, rectangular tube or plate stringers
  • Checker plate, grating, or plates on cleats for treads
  • Riser count and going from the height, with the comfort rule checked
  • Stringer lengths and cut angles, the landing frame and deck

Not on this drawing yet

  • Railings and handrails: coming soon
  • U-shaped stairs (180° turn), winders and spiral stairs
  • Landing supports and fixings to the structure
  • Structural design and building-code compliance

A first draft for review. You sign it off.

Metal Draw AI creates a fast first draft for review, quoting and documentation. It doesn't do structural calculations, engineering approval or code checks. Always check dimensions, materials, connections and safety requirements before fabrication.

Common questions

Do I need to work out the risers myself?
No. Give the height to climb and it picks the riser count closest to a comfortable riser, puts any landing exactly on a step, and lists what it chose. Give your own count or going and it uses yours.
Which stairs can it draw?
Straight stairs, and two flights on a landing that continue in line or turn 90° left or right. U-shaped stairs, winders and spiral stairs aren't drawn yet.
Does it draw the railing?
Not yet, railings are coming soon. The drawing notes that the railing, the landing supports and the fixings to the structure are still to be confirmed.
What do I get for the shop?
A stringer detail with its length along the top edge and its cut angles, and a cut list of stringers, treads and the landing frame and deck. Use it for quoting and on the saw once you've checked it.
Can I change it after the first drawing?
Yes. Ask in plain English, like "make it 1200 wide", "turn left at the landing" or "grating treads", and the whole stair is recomputed.
Does it check building codes?
No. It applies a comfort rule to the riser and going, but it doesn't check building codes or do structural design. Have the stair checked by a qualified person before you build.

Draw your next stair

Take the height and width from your next stair enquiry and see the drawing and cut list it makes.

Draw a Stair

Free: up to 20 drawings a month, no credit card.